Fire Protection Measures for Steel Structure Aircraft Hangars

Fire Protection Measures for Steel Structure Aircraft Hangars

Ensuring the safety and integrity of steel structure airplane hangars is crucial, especially regarding fire protection. These hangars often house expensive aviation equipment and fuel, potentially devastating a fire. In this article, Xinguangzheng Group explores various fire protection measures necessary for steel structure airplane hangars, from passive to active fire protection, and how to conduct effective fire risk assessments.

Table of Contents

The Importance of Fire Protection in Steel Structure Airplane Hangars

Implementing fire protection measures in steel structure airplane hangars is essential due to the high-risk factors involved. A significant danger is the large amounts of aviation fuel stored and handled within these facilities. Additionally, flammable materials such as lubricants, cleaners, and various chemicals further increase the fire risk. The large open spaces in hangars can also facilitate the rapid spread of fire and smoke.

The consequences of a hangar fire can be catastrophic. The potential loss of life is the most severe outcome, affecting not only staff but also emergency responders. Fires can cause significant economic losses by destroying high-value aircraft and infrastructure. Furthermore, fires can disrupt aviation operations, leading to delays, cancellations, and logistical challenges, ultimately impacting the entire aviation network.

Regulatory Standards and Compliance

Compliance with regulatory standards is vital for fire safety in airplane hangars. The International Building Code (IBC) provides a comprehensive framework for designing and constructing safe buildings, including hangars. The NFPA 409: Standard on Aircraft Hangars is another key standard that details specific fire protection requirements for different hangars, including steel structure hangars.

Local and national fire codes must also be followed, providing additional guidelines and requirements based on regional considerations and risks. These codes often mandate the installation of fire detection and suppression systems, proper ventilation, and the use of fire-resistant materials.

Insurance requirements play a critical role in ensuring adherence to fire safety standards. Insurance companies typically require specific fire protection measures as a condition of coverage, including regular maintenance and inspection of fire protection systems, staff training, and adherence to best fire management practices.

Important Matters About NFPA 409

NFPA 409 categorizes hangars into four major groups: Group I, Group II, Group III, and Group IV. These groups are based on factors such as the size of the hangar, the type of aircraft it houses, and the activities that take place in the hangar. Each category of hangar has its own fire safety rules. These rules are based on the risks associated with different types of hangars.

Group I Hangars

Group 1 hangars are usually the largest hangars and require extensive fire safety measures. This is because they store large quantities of fuel and other items that can catch fire. These hangars require at least one of the following safety measures:

  • Access doors into the aircraft are to be higher than 28 feet.
  • Individual fire zones greater than 40,000 square feet.
  • Accommodate aircraft with tail heights greater than 28 feet.

Group II Hangars

Group II hangars are not as large. Therefore, they must have both of the following:

  • Access doors into the hangar are less than 28 feet in height.
  • The space to accommodate the aircraft is between 12,000 and 14,000 square feet.

Group III Hangars

A Group III hangar must have either an in-line hangar that can accommodate multiple aircraft or an open hangar that can accommodate multiple aircraft. In addition, there may be a freestanding hangar that can accommodate a single aircraft. They must have both conditions:

  • The door to the aircraft must be less than 28 feet high.
  • The aircraft parking area does not exceed 12,000 square feet.

Type IV Hangars

Type IV hangars must have more aircraft parking space than Type III hangars. In addition, the rigid frame on which the metal hangar is constructed should be covered with a protective film.

The new provisions of NFPA 409 give hangar owners greater control over their fire safety programs. They can choose better fire suppression methods, such as encapsulants, if necessary. In addition, hangar operators should know how to use fire suppression devices and follow fire safety rules. This is necessary to keep the premises safe and in compliance with the regulations.

Fire Risk Assessment

Conducting a thorough fire risk assessment is essential for enhancing fire safety in hangars. This includes identifying potential ignition sources, such as electrical equipment, welding, other hot work processes, and static electricity. Understanding the location and control methods for these ignition sources is crucial.

Next, evaluating the fire load involves assessing the quantity and type of combustible materials present, such as fuel, lubricants, and structural components. Understanding the fire load helps in designing appropriate fire protection systems and selecting suitable fire-resistant materials.

Based on the risk assessment, develop risk mitigation strategies. These strategies may include implementing strict controls on ignition sources, improving cleaning practices to reduce combustible materials, and ensuring all fire protection systems are correctly designed, installed, and maintained. Regular training on fire procedures and emergency response is also a key component of risk mitigation.

Fire Protection Measures

Passive Fire Protection Measures

Passive fire protection measures aim to protect buildings and occupants by reducing the speed and spread of fire. Firstly, applying fire-resistant coatings to steel structures can delay the deformation of steel under high temperatures, providing valuable time for fire suppression and evacuation. Additionally, wrapping steel structures with fireproof insulation materials further enhances fire resistance. Separation measures such as firewalls and partitions are also important as they can effectively prevent the spread of flames and smoke within the building. The use of fireproof doors and windows can effectively block flames in case of a fire.

Ventilation of smoke and heat is also a vital part of passive fire protection. Natural ventilation systems discharge smoke and heat through skylights and vents, while mechanical ventilation systems ensure rapid smoke evacuation during a fire by installing exhaust fans and other equipment.

Active Fire Protection Measures

Active fire protection measures aim to reduce losses by detecting and extinguishing fires early. Automatic sprinkler systems are key among these, including wet, dry, and pre-action sprinkler systems, which are suitable for different environments. Properly designing and installing sprinkler systems ensures they cover all areas of the hangar and extinguish the fire promptly.

Combustible Liquid Drainage Floor Assemblies

This rule states that flammable materials must be removed from the hangar floor quickly and safely to prevent the spread of fire. This requirement was added by the NFPA Technical Panel in 2021. It is the same as for conventional foam fire suppression systems.

Automatic Sprinkler Systems

NFPA 409 requires a specific type of automatic sprinkler system for each hangar group. This ensures that the size of the hangar does not affect its fire suppression capability. This keeps sprinkler systems in Category II hangars from performing hazardous work.

Foam Fire Extinguishing Systems

Certain types of fire hazards in hangars can be extinguished with foam extinguishing devices. In the 2022 edition of NFPA 409, the requirements for foam were modified. This allows hangar workers to use new extinguishing agents, such as encapsulants, for high-risk protection. Encapsulant fire suppression systems can quickly extinguish a wide range of fires with minimal damage to aircraft and equipment.

These devices are important for ensuring fire safety in aircraft hangars. They activate when signs of fire are sensed. This greatly limits the spread of fire and minimizes property damage.

In addition, fire detection and alarm systems are equally important. Smoke detectors and heat detectors can quickly detect fires, alerting personnel through sound, lights, and networked alarm systems to evacuate and initiate fire suppression procedures. Foam fire suppression systems are suitable for fuel fires, covering the fire source and cutting off oxygen, while gas fire suppression systems are suitable for electrical fires, extinguishing fires by discharging inert gas. Water mist fire suppression systems efficiently cool the fire source and suppress fire spread.

Emergency Response and Evacuation

Emergency response and evacuation plans are crucial for ensuring personnel safety. Clear evacuation routes and signage ensure that personnel can quickly find exits during a fire. Regular fire drills and training improve the response capabilities and proficiency of staff.

Emergency response teams play a key role in fire incidents. Clearly defining team responsibilities and tasks ensures everyone knows their role. Coordination with local fire departments is also essential to ensure rapid support during emergencies.

On-site medical facilities and first aid equipment must also be in place. Ensuring sufficient first aid supplies and training staff in first aid allows for the timely treatment of injured personnel during a fire. By integrating these measures, the fire safety of steel structure airplane hangars can be significantly improved, ensuring the safety of personnel and property.

Steel Structure Aircraft Hangars construction-Xinguangzheng Group

Best Practices for Fire Management

Regular maintenance and inspection are crucial in fire management for steel structure airplane hangars. Regularly inspecting fire protection systems to ensure their proper functioning and keeping documentation records helps track maintenance history and identify potential issues.

Training and education are also key components. Implementing comprehensive fire training programs enhances staff awareness and emergency response capabilities. Additionally, raising fire awareness and alertness among hangar personnel through promotional activities is important.

How Xinguangzheng Group Ensures Fire Safety

Xinguangzheng Group has a unique design concept in fire safety. Fire safety factors are integrated from the design stage, providing customized solutions based on customer needs.

In terms of materials and technology, Xinguangzheng Group uses high-quality fire-resistant materials and employs the latest fire suppression and detection technologies to ensure the fire performance of hangars meets the highest standards.

Conclusion

As a designer and manufacturer of steel structure airplane hangars, Xinguangzheng Group understands the importance of fire safety. We are committed to ensuring the fire performance of hangars meets the highest standards by using the most advanced materials and technologies.

By using fire-resistant coatings and fireproof insulation materials, as well as installing firewalls and fireproof doors and windows, we effectively slow the spread of fire. Our ventilation systems are designed to naturally vent smoke and quickly remove smoke through mechanical means.

We also offer comprehensive active fire protection measures, including designing and installing automatic sprinkler systems, fire detection and alarm systems, and various fire suppression systems, such as foam, gas, and water mist systems. Regular inspections and maintenance ensure all fire protection systems are always in optimal condition.

Emergency response and evacuation plans are part of our safety management. We develop clear evacuation routes, conduct regular fire drills, and closely cooperate with local fire departments to ensure a rapid response in emergencies. We also emphasize equipping on-site medical facilities and first aid equipment to ensure personnel receive timely assistance during a fire.

FAQ

Common ignition sources include electrical equipment failures, high temperatures and sparks from welding and cutting, sparks from static electricity and mechanical friction, and stored flammable materials.

Fire protection systems should be inspected monthly for basic checks, quarterly for comprehensive inspections, and annually by professional technicians for detailed inspections and maintenance to ensure proper functioning.

Insurance companies require compliance with fire protection standards, regularly evaluate fire protection measures, and ensure adherence to the latest safety regulations. Compliance not only ensures compensation but also protects the safety of personnel and property.

Facebook
Twitter
LinkedIn
Reddit
James-Xinguangzheng Blog Editor
Content Writer

James is a senior steel construction expert at Xinguangzheng, specializing in solutions for industrial and commercial projects. He has extensive project management and design experience and shares insights on sustainable building and steel structure innovations by writing articles.

About Xinguangzheng

Founded in 1997, Xinguangzheng Steel Structure Group has over 27 years of professional experience in the steel structure industry. We have completed more than 5,000 projects in more than 130 countries around the world and hold international certifications such as EN1090 (CE) and ISO9001. Whether it is a complex industrial building or a large commercial facility, Xinguangzheng is always able to provide high quality and reliable steel structure solutions for our customers.

Categories
Latest News
Contact Information

Contact With Us

Scroll to Top

GET A QUOTE TODAY